LOUDNESS AS A FUNCTION OF THE DURATION OF AUDITORY STIMULATION |
| |
Authors: | Gö sta,Ekman ,Birgitta,Berglund Ulf,Berglund |
| |
Affiliation: | Psychological Laboratories, University of Stockholm, Sweden |
| |
Abstract: | The perceived loudness of a 1000 c/s tone was measured by a direct scaling method under different conditions of intensity (19–35 db) and duration (50–500 msec) of stimulation. It was found that loudness grows as a logarithmic function of stimulus duration; the relation was verified for ten individual subjects and four levels of intensity. In addition, the relation between temporal threshold and level of intensity was tentatively described. |
| |