ODAP: a stand-alone program for observational data acquisition |
| |
Authors: | William P. Hetrick Robert C. Isenhart Derek V. Taylor Curt A. Sandman |
| |
Affiliation: | 1. State Developmental Research Institute, Fairview, Costa Mesa, California
|
| |
Abstract: | A software program written to collect real-time, observational data is described. The flexible program allows customized behavior codes and observational durations and simultaneously records both timed and counted events. The data are collected by means of single keystrokes, automatically stored to disk with 100th of a second resolution and summarized for each observational session. The program’s database files are dBASE III PLUS compatible and may be browsed, edited, or converted to ASCII files from the program’s main menu. Field testing demonstrated the efficiency and interobserver reliability of the program (for frequency,r=0.81; for durational behaviors,rs=0.89 and 0.96). The software operates on IBM XT/AT/PS 2s and most clones with PC/MS DOS version 2.0 or greater. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|