首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Calibration of a color monitor for visual psychophysics
Authors:Andrew B Metha  Algis J Vingrys  David R Badcock
Institution:1. Department of Optometry, University of Melbourne, 3052, Parkville, VIC, Australia
Abstract:It has become common for stimuli used in visual psychophysical experiments to be presented on high-resolution color cathode-ray tubes (CRTs) such as the Barco CDCT 6551. These enable a flexibility of color, spatial-frequency content, temporal-frequency content, duration, size, and position that is not provided by most other media. CRTs are, however, not perfect; they suffer from the effects of temporal instability, spatial variability, lack of phosphor constancy, gun interdependence, and gun nonlinearity. This paper describes methods of assessing these aspects of monitor performance with respect to how significant each may be in psychometric terms. Although every application of CRT use in visual psychophysics is different, some general rules can be formulated to help ensure that unwanted effects are kept to a minimum. For the CRT used in this study (Barco CDCT 6551), a warm-up time of 30-45 min is necessary before chromatic and luminous stability ensues. Restriction of individual gun outputs to within 10%-90% of the possible range ensures that the effects of gun interdependence and lack of phosphor constancy are negligible. Calibration methods dealing with the linearization of gun output are also discussed.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号