首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Reduction and calibration of eye monitor data
Authors:Reinhold Kliegl  Richard K Olson
Institution:1. Department of Psychology, University of Colorado, 80309, Boulder, Colorado
Abstract:The present paper presents FORTRAN programs for reducing eye monitor output to fixations and for mapping these fixations to locations in the stimulus space. Flexible parameters of the fixations program allow for determination of the beginning and end of fixations under different resolution criteria and for indicating loss of accurate measurement. The calibration program is based on a rectangular 9-point fixation grid. Each fixation is rescaled within this grid by solving for a quadratic equation. The rescaled values are output in a flexibly determined rectangular coordinate system that is related to the stimulus space, such as character position on the screen. The programs were developed for the 60-Hz Applied Sciences corneal reflection eye monitor, but they may be used with a number of other systems.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏