首页 | 本学科首页   官方微博 | 高级检索  
     


A real time multi-angle adjustable phased high intensity focused ultrasound system
Affiliation:1. Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China;2. Shanghai Shende Medical Technology Co., Ltd, Shanghai, China;1. Department of Electronics and Instrumentation Engineering, B.S. Abdur Rahman Crescent Institute of Science and Technology, Chennai, India;2. Faculty of Computers and Information, Mansoura University, Egypt;3. Department of Computer Applications, Alagappa University, Karaikudi, India;1. Department of Surgery, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea;2. Department of Radiology, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea;1. Department of Colorectal Surgery, Digestive Disease Institute, Cleveland Clinic, 9500 Euclid Ave, Cleveland, OH 44195;2. Cleveland Clinic Lerner College of Medicine, Cleveland, OH;3. Center for International Medical Education, Education Institute, Cleveland Clinic, Cleveland, OH;1. Department of EIE, Dr. Mahalingam College of Engineering and Technology, Pollachi, Coimbatore, India;2. Department of EEE, Dr. Mahalingam College of Engineering and Technology, Pollachi, Coimbatore, India;1. EEE Dept, Kamaraj College of Engineering and Technology, Virudhunagar, Tamil Nadu, India;2. EEE Dept, Mepco Schlenk Engineering College, Sivakasi, Tamil Nadu, India;1. Department of Electronics and Communication Engineering, Sethu Institute of Technology, Madurai 625019, India;2. Department of Electronics and Communication Engineering, VMKV Engineering College, Vinayaka Mission''s Research Foundation, Salem 636308, India;3. Ciddse Technologies Pvt Ltd, Chennai 600087, India
Abstract:High Intensity Focused Ultrasound (HIFU) is identified as the truly non-invasive modality enabling tumor heating and ablation in treatment of breast tumor, uterine fibroid, bone tumor, prostate carcinoma, hepatic carcinoma, pancreatic neoplasm, and so on. However, as the conventional transducers are fixed on the probe relatively without position changes, there is a severely limit for the movable range of the focus. This article mainly introduced a real time multi-angle adjustable Phased High Intensity Focused Ultrasound (PHIFU) system, which could implement focusing at different positions by adjusting the angles between disparate transducers in real time under the driving of digital servos. The angle detectors are installed between two digital servos to acquire the precise angles in order to feed back to the system. In return, the angles could be also calculated if the position of the focus was given. This way improved the scope of the focused ultrasound therapy greatly from the results of the acoustic field simulations.
Keywords:PHIFU  Digital servos  Angle detector  Acoustic field simulations  Position adjustable
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号