首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Comparison of the RT3 Research Tracker and Tritrac R3D accelerometers during a backpacking expedition by a single subject
Authors:DeVoe Dale
Institution:Department of Health and Exercise Science, Colorado State University, Fort Collins, 80523, USA. devoe@cahs.colostate.edu
Abstract:This study compared the RT3 Research Tracker accelerometer and the Tritrac R3D accelerometer in a field setting. A six-day backpacking expedition (122.4 km in length) was completed by a single subject in the Grand Canyon National Park, Arizona. The overall correlation between the counts of vector magnitude activity for the RT3 and R3D was moderate (r =.75, p<.001), with the overall calculated bias mean difference (RT3 minus R3D) and standard deviation of the differences] across all six days estimated at 235+/-436 vector magnitude activity counts. However, agreement between the instruments is problematic; the RT3 might be 201 activity counts below or 671 activity counts above the R3D in assessing physical activity during backpacking.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏