首页 | 本学科首页   官方微博 | 高级检索  
     


Control of oscillatory force tasks: Low-frequency oscillations in force and muscle activity
Affiliation:1. Motor Behavior Laboratory, Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL, USA;2. Neuromuscular Physiology Laboratory, Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL, USA;1. Department of Rehabilitation Sciences, Faculty of Health Sciences, Hokkaido University, Sapporo, Japan;2. Department of Physical Therapy, School of Rehabilitation, Tokyo Kasei University, Sayama, Japan;1. Affordance Perception-Action Laboratory, School of Kinesiology, University of Minnesota, USA;2. Department of Psychology, Illinois State University, USA;1. Musculoskeletal Rehabilitation Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran;2. School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:Force variability during steady force tasks is strongly related to low-frequency oscillations (<0.25 Hz) in force. However, it is unknown whether low-frequency oscillations also contribute to the variability of oscillatory force tasks. To address this, twelve healthy young participants (21.08 ± 2.99 years, 6 females) performed a sinusoidal force task at 15% MVC at two different frequencies (0.5 and 1 Hz) with isometric abduction of the index finger. We recorded the force from the index finger and surface EMG from the first dorsal interosseous muscle and quantified the following outcomes: 1) trajectory variability and accuracy; 2) power spectrum of force and EMG bursting below 2 Hz; 3) power spectrum of the interference EMG from 4 to 60 Hz. The trajectory variability and error significantly increased from 0.5 to 1 Hz task (P < 0.01). Increased force oscillations <0.25 Hz contributed to greater trajectory variability and error for both the 0.5 and 1 Hz oscillatory task (R2 > 0.33; P < 0.05). The <0.25 Hz oscillations in force were positively associated with greater power in the <0.25 Hz for EMG bursting (R2 > 0.52; P < 0.01). The modulation of the interference EMG from 35 to 60 Hz was a good predictor of the <0.25 Hz force oscillations for both the 0.5 Hz task and 1 Hz task (R2 > 0.66; P < 0.01). These results provide novel evidence that, similar to steady contractions, low-frequency oscillations of the motor neuron pool appear to be a significant mechanism that controls force during oscillatory force tasks.
Keywords:Trajectory variability  Accuracy  Low-frequency oscillations  Oscillatory force tasks
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号