首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Perceptual cues used in reproduction of inspired volume
Authors:Lawrence J Folinsbee  Jeffrey A Gliner  Steven M Horvath
Institution:1. University of California, 93106, Santa Barbara, California
Abstract:Man is capable of reproducing an inspired lung volume (IV) with relative precision (±3 %–8 %). To investigate the importance of cues which may be used to determine IV, we performed two experiments. In each, the subject inspired a “standard” breath (from resting end~xpired lung volume) corresponding to 25%, 50%, or 75% of inspiratory capacity (IC) and then expired nearly completely. From this expired volume, the subject either tried to reproduce the tidal volume (i.e., volume of air inspired) of the first breath (volume reproduction) or to reproduce the previous end-inspired lung volume (position reproduction). The constant error indicated that subjects overestimated tidal volume by about 200 ml. Despite this overestimation, the variability of reproduction was less for volume reproduction than for position reproduction when IV was small. The JND for volume reproduction increased linearly with increasing IV, whereas the JND for position reproduction was similar at all IVs so that the Weber ratio decreased. These observations suggest that, in the perception of inspired volume, the sensation of end-inspired position is important when the inspired volume is large, but that subjects apparently rely on some other cue to reproduce small lung volumes accurately.