首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Tracking the line of primary gaze in a walking simulator: modeling and calibration.
Authors:James Barabas  Robert B Goldstein  Henry Apfelbaum  Russell L Woods  Robert G Giorgi  Eli Peli
Institution:Schepens Eye Research Institute, Harvard Medical School, Boston, Massachusetts 02114, USA.
Abstract:This article describes a system for tracking the line of primary gaze (LoPG) of participants as they view a large projection screen. Using a magnetic head tracker and a tracking algorithm, we find the onscreen location at which a participant is pointing a head-mounted crosshair. The algorithm presented for tracking the LoPG uses a polynomial function to correct for distortion in magnetic tracker readings, a geometric model for computing LoPG from corrected tracker measurements, and a method for finding the intersection of the LoPG with the screen. Calibration techniques for the above methods are presented. The results of two experiments validating the algorithm and calibration methods are also reported. Experiments showed an improvement in accuracy of LoPG tracking provided by each of the two presented calibration steps, yielding errors in LoPG measurements of less than 2 degrees over a wide range of head positions. Source code for the described algorithms can be downloaded from the Psychonomic Society Web archive, http://www.psychonomic.org/archive/.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号