Assessing muscular fatigue with a portable tremor measurement system suitable for field use |
| |
Authors: | Traci L. Galinsky Roger R. Rosa Daniel D. Wheeler |
| |
Affiliation: | 1. Division of Biomedical and Behavioral Science, Robert A. Taft Laboratories, National Institute for Occupational Safety and Health, 4676 Columbia Parkway, 45226-1998, Cincinnati, OH 2. University of Cincinnati, Cincinnati, Ohio
|
| |
Abstract: | The utility of a portable tremor measurement system for detecting muscle fatigue was evaluated. Static arm extension was used to induce fatigue. A probe containing two accelerometers, held in the extended hand, recorded horizontal and vertical tremor oscillations in the 1- to 18-Hz range. Several summary amplitude and frequency measures were then derived to analyze hand/arm tremor in the unfatigued and the fatigued states. Large increases from unfatigued to fatigued states were observed in all of the amplitude measures in both axes. Summary frequency measures were far less sensitive to fatigue. Correlations between consecutively measured observations revealed high levels of reliability (r τ .80) in all of the amplitude measures, but not in the frequency measures. The most robust index of fatigue was the total power in the entire 1- to 18-Hz spectrum. The other amplitude measures, however, are suitable for examining the effects of fatigue in isolated portions of the spectrum. |
| |