A self-contained,regulated, burst-firing constant-current ac shock generator |
| |
Authors: | Joseph S. Ali Lawrence Reiter |
| |
Affiliation: | 1. Experimental Biology Division, Health Effects Research Laboratory, U.S. Environmental Protection Agency, 27711, Research Triangle Park, North Carolina
|
| |
Abstract: | A line- and load-regulated constant-current ac shock generator has been designed for animal behavior experiments. The self-contained unit has four operating modes, amplitude adjustment, and a leakage current detection circuit. A unique feature of this generator is that the good load regulation achieved by using a high-voltage source is preserved without such problems as arcing and high current density effects. Circuit schematics, along with a discussion of selected circuits, are included. Experimental data are presented to demonstrate the utility of the device. |
| |