首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   45篇
  免费   1篇
  2023年   1篇
  2021年   1篇
  2018年   2篇
  2017年   2篇
  2016年   1篇
  2013年   5篇
  2012年   3篇
  2011年   5篇
  2010年   2篇
  2008年   4篇
  2007年   2篇
  2006年   5篇
  2005年   2篇
  2004年   3篇
  2003年   1篇
  2002年   3篇
  2000年   1篇
  1992年   1篇
  1991年   1篇
  1975年   1篇
排序方式: 共有46条查询结果,搜索用时 218 毫秒
21.
The purpose was to examine the properties and reproducibility of the force-decreasing curve and muscle-oxygenation kinetics measured by near infrared spectroscopy in sustained isometric grip and rhythmic repeated grip measurements using various contraction intervals (2 to 5 sec.). 10 healthy young adults performed both grip tests for 6 min., during which muscle-oxygenation kinetics were measured. The intraclass correlation coefficients of the time to reach the minimum value for oxygenated hemoglobin and myoglobin tended to become lower with longer relaxation time, especially over a 3-sec. interval. Although blood-flow obstruction closely influences the initial decreasing grip force during both grip tests with a 2-sec. interval, the decreasing grip force during rhythmic repeated gripping with over a 3-sec. interval is low. Hence, the physiological mechanism related to rhythmic repeated grip with over a 3-sec. interval may differ from that related to sustained isometric grip and rhythmic repeated grip with a 2-sec. interval.  相似文献   
22.
This study assessed sex and individual differences in sway-position and velocity power spectra and reliability of power frequency with 30 health young people. The body sway for 1 min. was measured twice over a 1-min. rest. There were no significant sex differences in the spectra. Frequency bands with a large coefficient of variance over 10.0 appeared up to 0.6 Hz. 75% relative accumulated power frequency appeared at 1.10-1.23 Hz in the position and at 2.00-3.05 Hz in the velocity spectra. Most power was in the low frequency band (A and B frequency intervals) of the international standard. Relative accumulated power frequency of position and velocity power spectra was reasonably reliable. It may be necessary to establish a new evaluation frequency interval by direction of sway-position and velocity using relative accumulated power frequency for healthy people.  相似文献   
23.
This study was done to examine the influence of instructions on the evaluation of rhythmic repeated muscular endurance, that is, the ability to continue muscle-power exertion at a regular interval. 15 healthy young male adults performed maximal repeated rhythmic grips for 6 min. under the following three instruction conditions: (1) "Squeeze freely during the 2-sec. interval," (2) "Squeeze quickly and then relax," and (3) "Squeeze quickly and then hold the exertion for 1 sec." Time to peak force was slower in Condition 1 than in Condition 2. A decline in exertion of force was found for all conditions after 1 min. The decline in rate of the peak values in Conditions 1 and 3 was about 10 to 15% larger than that of Condition 2. In conclusion, proper instructions are necessary, even for a short 2-sec. interval, when evaluating muscular endurance with repeated rhythmic grips. Condition 2 instruction may be most effective.  相似文献   
24.
During passive and active listening tasks electrodermal activity of 49 healthy school children was studied. The procedure included baseline recording, a passive listening task, instructions, and simple and discriminative active-listening tasks. On the passive task from Trials 1 to 10, habituation of the amplitude of the skin conductance response (SCR) occurred. Habituation of SCR amplitude did not occur during the active tasks. The children seemed to pay more attention during the active tasks than during the passive task, since the need to press the key is apt to require and may even increase general attention. As for temporal variables of SCR, the frequency of spontaneous SCRs showed a significant negative correlation with SCR latency and rise time. Reaction time exhibited a significant negative correlation with age. An increase in reaction time was found during the discriminative active-listening task over that for the simple active-listening task during the course of 10 trials. The younger children (6-8 yr.) seemed to require longer to pay attention than the older ones (10-12 yr.). Children seemed to pay more attention during the discriminative than during the simple active-listening task, since the need to press the key for discrimination should require and is likely to increase general attention.  相似文献   
25.

A phase transformation in γ-TiAl intermetallic alloy was found to be induced with 50keV Xe-ion irradiation-implantation at doses larger than 2.2 x 1018 ions m-2 at room temperature. The structure and the chemical composition of the induced phase were investigated with high-resolution transmission electron microscopy and energy-dispersive X-ray spectroscopy. The zones of the induced phase have sizes up to about several tens of nanometres. The phase has a hexagonal structure with a = 0.286 nm and c = 0.462nm. The crystallographic orientation relationship between the phase (P) and the gamma-TiAl matrix is (001)P//(111)γ and \[100]P//[011]γ. The \[Al]/[Ti] atomic composition ratio in the phase is analysed to be 56/44, slightly different from that of the matrix, 51/49. These results suggest that the induced phase is an Al solid solution of α-Ti alloy phase, which has different structural parameters and chemical composition from those of the reported phase. It is suggested that the size of the ions is important in the phase transformation.  相似文献   
26.

Mechanical alloying of Ti 45 Zr 38 Ni 17 powder mixture forms an amorphous phase, but subsequent annealing causes the formation of an icosahedral ( i ) phase. The maximum hydrogen concentration that can be loaded at 573K at a hydrogen pressure of 3.8MPa is the same (\[H]/\[M] 1.5) for the amorphous and i -phase powders. With hydrogenation, the i -phase is almost stable, forming no hydrides, whereas the amorphous phase transforms to a fcc hydride. The activation energy for hydrogen desorption for the i -phase is about 127kJmol -1, which is lower than that for the amorphous phase, suggesting that the i -phase powder may have better properties for hydrogen-storage applications.  相似文献   
27.
28.
We report a patient who has had persistent visual disturbances since she underwent catheter ablation to treat her Wolff-Parkinson-White (WPW) syndrome. We examined her visual symptoms carefully and quantitatively by means of our newly developed method combining image-processing and psychophysics. We first simulated the patient's visual symptoms using image-processing techniques. Since the simulation indicated that she would be very sensitive to the edges of the visual stimuli, we evaluated her sensitivity to the edges using psychophysics. The results indicated that she was hypersensitive to the clear-cut edges of the visual stimuli. Her visual symptoms were very similar to those of visual aura of migraine, rather than those of photosensitive epilepsy. Magnetic resonance imaging (MRI) and single photon emission computed tomography (SPECT), electroenchepalogram (EEG), and visual-evoked potentials (VEP) in the patient were normal. No abnormalities in her fundus, visual field, or electroretinogram were found, either. Transesophageal echocardiography with bubble study indicated that she had a preexisting right-to-left shunt. We hypothesize that visual aura of migraine was triggered and made persistent by the catheter ablation in this patient. Although the relationship between migraine, catheter ablation, and right-to-left shunts is unknown, previous studies on the transcatheter closure of patent foramen ovale suggest a possible link between them. Catheter ablation in patients with migraine and preexisting shunts may lead to exacerbations in migraine symptoms.  相似文献   
29.
The goal was to describe static one-legged balance during use of a lifted leg and to compare balance between the dominant and nondominant legs of soccer players. Participants were 17 male soccer players and 17 untrained male students (control). Balance ability was evaluated with four sway measures: sway velocity, anterior-posterior sway, medial-lateral sway, and high-frequency sway. Soccer players had smaller magnitude mean anterior-posterior and medial-lateral sway than untrained students. Although mean sway velocity and anterior-posterior sway were higher with the dominant leg than in the nondominant leg of the control group, there was no significant difference on any sway factor between the two legs of the soccer group. In conclusion, the soccer players were observed to have superior static one-legged balance during use of a lifted leg, and there is no difference in balance for the two legs in the soccer group.  相似文献   
30.
In the paper, we present a multi-aspect data analysis approach for investigating human computation mechanism. Multi-aspect analysis in multiple human brain data sources is an important methodology in Brain Informatics, which emphasizes on a systematic way for investigating human information processing mechanisms, including measuring, collecting, modeling, transforming, managing, and mining multiple human brain data obtained from various cognitive experiments by using powerful equipments, such as fMRI and EEG. After giving an outline of Brain Informatics methodology, we describe how to design cognitive experiments of mental arithmetic task with multiple difficulty levels for obtaining multiple EEG and fMRI data sources, and how to analyze such data for investigating the spatiotemporal characteristics and flow of human computation processing. Such an investigation can be regarded as a case study using Brain Informatics methodology. Experimental results show the usefulness of our approach.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号