首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A system is described involving three tape recorders and a control device whereby dichotic tapes can be prepared with onset alignment accurate to a few milliseconds, or to a measured asynchrony if required. No modifications of any sort are necessary for the three tape recorders. The two channels are separately recorded in the speaker’s own time, the only requirement being that the separate words be spoken with an interword interval of 350 msec or more, to provide sufficient time for starting and stopping the system. A tone burst is placed directly on tape on another channel ahead of each word, the latter being delayed by recording in tandem through two tape recorders. The first recorder is set to the delay (echo, NAB) facility, while the tone is recorded directly on the second. Subsequently, when this is done for each item on the two speech channels, the device, described below. utilizes the tone bursts to align the two input recorders. It then rerecords each pair of words on to the third (output or dichotic) machine, to the desired synchrony/asynchrony, and interitem interval. The system can be left to align the two channels automatically. A maximum repetition rate of two dichotic pairs every 1.3 sec can be achieved with Revox A77 tape recorders.  相似文献   

2.
3.
A simple method for producing audio tapes with temporally synchronized messages is described. The duration and spacing of words can be precisely controlled. This method requires a minimum of elaborate equipment, yet synchronization is very accurate with highly intelligible speech.  相似文献   

4.
5.
6.
It is almost universally accepted that traditional provider-patient relationships should be governed, at least in part, by the ethical principles set forth by Beauchamp and Childress (Beauchamp and Childress, Principles of biomedical ethics, 1979). These principles include autonomy, beneficence, non-maleficence and justice (Beauchamp and Childress, Principles of biomedical ethics, 1979). Recently, however, the nature of medial practice has changed. The pervasive presence of computer technology in medicine raises interesting ethical questions. In this paper we argue that some software designers should be considered health care providers and thus be subject the ethical principles incumbent upon “traditional” providers. We argue that these ethical responsibilities should be applied explicitly rather than as a passive, implicit, set of guidelines.  相似文献   

7.
8.
9.
The usefulness of comparing dream psychology and neurosis psychology is demonstrated in the teaching of a course on the theory of technique at the Pittsburgh Psychoanalytic Institute. Candidates are assigned the task of writing a five-minute segment of free associations using assigned background material, resistances to be demonstrated, and assigned current and past conflicts. The candidates then present their free associations to the class for analysis. Explication of educational and developmental issues is given.  相似文献   

10.
A new apparatus has been developed for the simple, safe, and effective delivery of electric shock. It delivers a single-pulse high-voltage shock of very short duration. Both voltage and current are easily measured and the applied energy can be calculated. Constant energy applications depend less upon skin contact resistance than is the case with 600-V 60-Hz shockers.  相似文献   

11.
A device for inverting the visual field of small animals is described. Binocular lenses are mounted in a lightweight, aluminum frame which, in turn, is secured to a surgically attached, dental acrylic skull cap. The construction of the device, and its usefulness when simultaneous electrophysiological recordings are desired, is described by illustrating the details of fabricating such a device for a cat.  相似文献   

12.
Controlling experiments with paper-tape readers often requires the production of complex paper tapes. A program was written to allow automatic production and checking of complex punched paper tapes using a small computer. The user first defines the punches or punch sets to be used. He then specifies, for each successive block of tape to be punched, the number of punch sets of each type to occur and whether those punch sets should be copied in order or automatically randomized. The specified tape is then produced using a two-pass procedure, after which the tape may be automatically checked for punching errors if desired. The program has facilities for retention or modification of user commands from previous runs, simplifying the production of a large number of tapes with similar characteristics.  相似文献   

13.
14.
15.
16.
17.
This article briefly describes a system of analyzing movement sequences extracted from video images. The system uses an IBM-PC or compatible computer, equipped with a CGA screen and a mouse, and a videotape recorder and monitor. The coordinates of the points selected from the images with the mouse are stored in an ASCII-format file by a computer program. The principle behind this system is that it projects video images on a computer screen through a one-way mirror while avoiding parallax effects.  相似文献   

18.
A simple and sensitive device for measuring the volume of small biological specimens such as eyes or brains is described. This easily constructed volumeter is more accurate than a graduated cylinder and does not compromise the integrity of the tissue.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号