首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A combined forward-backward masking procedure was used to investigate the threshold of a 30-msec, 500-Hz signal as a function of masker frequency. The signal thresholds were obtained in two signal conditions, diotic (So) and dichotic (Sπ), and for two different temporal separations of the maskers. The maskers were 500 msec in duration and were presented at 75 dB SPL. The function relating masked signal threshold to masker frequency was used to describe frequency selectivity in the four conditions. There were no differences in frequency selectivity measured between the diotic and dichotic signal conditions and only a small difference measured between the two intermasker interval conditions. The Sπ conditions yielded lower thresholds than did the So conditions. The change in intermasker interval from 10 to 50 msec lowered the threshold maximally 18 dB for the So condition and 13 dB for the Sπ condition. The results indicate that in this tonal temporal masking procedure there are no differences between the diotic and dichotic critical bands.  相似文献   

2.
In adult listeners, the signal-to-noise ratio at masked threshold remains constant with increases in masker level over a wide range of stimulus conditions. This relationship was examined in 7-month-old infants by obtaining masked thresholds for .5- and 4-kHz tones presented in four levels of continuous masking noise. Adults were also tested for comparison. Masker spectrum levels ranged from 5 to 35 dB/Hz for .5-kHz tones, and from -5 to 25 dB/Hz for 4-kHz stimuli. Thresholds were determined for stimuli of both 10 and 100 msec in duration. The results indicated that infants' performance was more adult-like for 4-kHz stimuli. Although mean thresholds for both 10- and 100-msec, 4-kHz tones were approximately 7 dB higher in infants than in adults, E/N0 at threshold remained essentially constant over the 30-dB range of maskers employed. By contrast, infants' thresholds for .5-kHz tones were exceptionally high at lower levels of the masker. Threshold E/N0 decreased significantly as masker level increased from 5 to 35 dB/Hz, and this decrease was significantly greater for 10- than for 100-msec stimuli. Temporal summation of .5-kHz tones, measured as the difference between thresholds obtained at the two signal durations, was greater for infants than for adults at low levels of the masker. However, because infants' thresholds improved more rapidly with level for 10- than for 100-msec tones, age differences in temporal summation were no longer significant when masker spectrum level was 35 dB/Hz. These results suggest that the relationship between signal-to-noise ratio at masked threshold and level of the masker is dependent on both signal frequency and duration during infancy.  相似文献   

3.
In adult listeners, the signal-to-noise ratio at masked threshold remains constant with increases in masker level over a wide range of stimulus conditions. This relationship was examined in 7-month-old infants by obtaining masked thresholds for .5- and 4-kHz tones presented in four levels of continuous masking noise. Adults were also tested for comparison. Masker spectrum levels ranged from 5 to 35 dB/Hz for .5-kHz tones, and from ?5 to 25 dB/Hz for 4-kHz stimuli. Thresholds were determined for stimuli of both 10 and 100 msec in duration. The results indicated that infants’ performance was more adultlike for 4-kHz stimuli. Although mean thresholds for both 10- and 100-msec, 4-kHz tones were approximately 7 dB higher in infants than in adults, E/N0 at threshold remained essentially constant over the 30-dB range of maskers employed. By contrast, infants’ thresholds for .5-kHz tones were exceptionally high at lower levels of the masker. Threshold E/N0 decreased significantly as masker level increased from 5 to 35 dB/Hz, and this decrease was significantly greater for 10- than for 100-msec stimuli. Temporal summation of .5-kHz tones, measured as the difference between thresholds obtained at the two signal durations, was greater for infants than for adults at low levels of the masker. However, because infants’ thresholds improved more rapidly with level for 10- than for 100-msec tones, age differences in temporal summation were no longer significant when masker spectrum level was 35 dB/Hz. These results suggest that the relationship between signal-to-noise ratio at masked threshold and level of the masker is dependent on both signal frequency and duration during infancy.  相似文献   

4.
Vibrotactile difference thresholds for intensity were measured at several intensity levels of a test stimulus in the absence of a masking vibration and in the presence of three different amplitudes of a masking vibration. The test stimulus was a 160-Hz vibration delivered to the right index finger. The masking stimulus was a 160-Hz vibration delivered to the right little finger. For the same amplitudes of the test stimulus, △I varied as a direct function of the amplitude of the masking vibration. The smallest △Is resulted from measurements made in the absence of the masking stimulus. The Weber fraction, △I/I, was constant only for the more intense test stimuli in the absence of any masking stimuli. Independent of the presence or level of the masker, the Weber fraction for all stimuli approached approximately the same value, .25, when the test stimuli were raised to 20-dB sensation level. A model is proposed to account for the increase in the Weber fraction as a function of masker intensity and to predict masked thresholds.  相似文献   

5.
The detection threshold of a brief test stimulus was measured as a function of the onset asynchrony between it and a long-lasting suprathreshold masking stimulus. Both stimuli were sine-wave gratings of the same vertical orientation and in the peak-subtract phase but differed in spatial frequency by a factor of 3. The temporal masking functions obtained with 2- and 6-cycles/deg maskers of high contrast exhibited transient on- and off-peaks of masking and a sustained effect during the masker exposure. An 18-cycles/deg masker caused sustained masking only. Experiments with maskers of variable spatial frequency and contrast showed that, in the low-spatial-frequency range, the mechanism responsible for the transient effect was more sensitive than that generating the sustained effect, while the sustained effect required less contrast in the high-spatial-frequency range. The results are considered as evidence, in addition to previous findings, for the sustained/transient dichotomy in the temporal domain.  相似文献   

6.
The amounts of ipsilateral and contralateral masking obtained with a modified psychophysical procedure were compared for vibratory stimuli presented to different body loci. Results of a combined forced-choice localization task and a forced-choice detection task were similar to the results obtained in previous investigations which employed method of limits and two-alternative, temporal forced-choice procedures, respectively. Ipsilateral maskers produced similar amounts of masking in both the detection and localization tasks for fingertip and arm test sites. Contralateral maskers resulted in considerably more masking in the localization task than in the detection task for both fingertip and arm test sites. When large longitudinal distances were introduced between the test stimulus and masker, little masking was evident in either the localization or detection task. It was concluded that the differences in the amount of ipsilateral and contralateral masking obtained with different psychophysical procedures reflect different effects of a masker on the detectable attributes of a test stimulus. Implications of these results for the study of multiple tactile perception were discussed.  相似文献   

7.
Temporal masking of clicks by noise was investigated using forward and backward masking paradigms. Both the noise duration and the temporal separation, ΔT, between the click and noise were varied. For very brief ΔTs (100 microsec) and for very long ΔTs (100 msec), the duration of the masker did not greatly affect the click threshold. However, for intermediate ΔTs (3 msec), the threshold increased by as much as 44 dB as the noise duration increased from 0.1 to 100 msec. Temporal weighting functions, which describe the relative effectiveness of the noise as a function of ΔT, were computed from these data.  相似文献   

8.
在有多人同时说话的嘈杂环境中,为什么具有正常听力的人能在一定的程度上听懂目标语句?研究这个著名的“鸡尾酒会”问题的一个新进展是将干扰言语的作用区分出了能量掩蔽和信息掩蔽两种成分。与发生在外周系统的能量掩蔽不同,信息掩蔽发生在心理层次并受到认知过程的调节。因此,主观空间分离、与目标语句节奏相关的视觉信号以及对目标语句某些特征的熟悉程度等知觉线索都具有去掩蔽作用。考察可减少信息掩蔽的知觉线索的交互作用及其高级认知调节是今后重要的研究内容  相似文献   

9.
Masked threshold for a pure-tone signal can be substantially elevated whenever the listener is uncertain about the spectral or temporal properties of the masker, an effect referred to as auditory informational masking. Individual differences in the effect are large, with young children being most susceptible. When masker uncertainty is introduced by randomizing the frequencies of a multitone masker on each presentation, the function relating a child's pure-tone signal threshold to the number of masker components is found to be substantially elevated above that of most adults. The age effect and the individual differences among adults are not well understood, though a difference in the shapes of the masking functions suggests that different detection strategies may be involved. The present study reports results from a principal components analysis of informational masking functions obtained from 38 normal-hearing children ranging in age from 4 to 16 years and 46 normal-hearing adults ranging in age from 19 to 38 years. The premise underlying the analysis is that if different detection strategies are involved, they should add independent sources of variance to the masking functions. Hence, more than one principal component (PC) should be required to account for a substantial proportion of the variance in these functions. The results, instead, supported the operation of a single underlying strategy with all but 17% of the variance accounted for by the first PC within and across age groups. An analysis of variance on the first two PCs showed that only the first changed with age, and a cluster analysis of the masking functions showed complete separation of clusters along this PC for all but 1 listener. The results are taken to suggest that large individual differences informational masking at all ages reflect differences in the extent to which masker uncertainty adds variance to the decision variable of an otherwise optimal decision strategy.  相似文献   

10.
Subjects were required to identify vibrotactile patterns presented to their fingertips. The patterns, letters of the alphabet, were presented singly or in the presence of other vibrotactile masking stimuli. Two types of masking stimuli were used: an energy masker and a pattern masker. The effectiveness of these two types of maskers in interfering with letter recognition was tested, using them as forward and as backward maskers and presenting them at several different levels of intensity. The results showed more masking by the pattern masker, more backward than forward masking, and more masking as intensity increased. In addition, compared with the energy masker, the pattern masker showed both a greater difference between forward and backward masking and a greater increase in masking as masker intensity increased. The results are discussed in terms of a two-factor model of vibrotactfle masking.  相似文献   

11.
A series of experiments was conducted to determine the effects of method of threshold measurement on the amount of threshold shift produced by a masking stimulus. The amount of contralateral tactile masking of the fingertip was found to be much greater when thresholds were measured by the Békésy tracking method than when measured by a forced-choice method. When the Békésy tracking procedure was modified so that each observation interval containing a brief stimulus was followed almost immediately by a second observation interval not containing a stimulus, the amount of masking was substantially reduced for both contralateral tactile masking and auditorytactile masking and corresponded almost exactly with the amount of masking measured by the forced-choice method. No such reduction in the amount of masking was obtained by using this procedure to measure ipsilateral tactile masking or auditory masking.  相似文献   

12.
A pure tone was used to mask narrow and wide bands of noise centered on the frequency of the tone. In a given experimental session, the sound-pressure level (SPL) of the tone was held constant and loudness balances were obtained between a masked and unmasked noise band of equal width. These results are compared to earlier measures of the partial masking of tone by noise. The comparison shows that noise masks a tone more effectively than the tone masks the noise. Although the effect of the tone on a critical band of noise is greater than its effect on either an octave-band noise or wide-band noise, it is considerably smaller than the effect of the noise on the tone. Decreasing the noise bandwidth still further to a subcritical width reduces the asymmetry of masking somewhat, but a difference at high intensities of about 20 dB between the masking effects of an equally intense noise and tone remains. Whether the masker is a tone or noise, masking ceases when the effective energy of the masked and masking stimuli is the same.  相似文献   

13.
The effects of backward masker “fringe” on performance in homophasic and antiphasic masking conditions were investigated. The results of the study indicate that (1) the presence of a backward masker fringe has only a small effect on performance in homophasic masking conditions; (2) under antiphasic masking conditions, the presence of a backward masker fringe improves performance; (3) similar to the results of studies investigating the effects of forward masker fringe, the magnitude of the improvement in performance increases as the duration of the fringe increases; and (4) the magnitude of the improvement caused by the presence of backward masker fringe is considerably smaller than the magnitude of the improvement caused by the forward masker fringe. It appears, then, that the presence of backward masker fringe may provide a baseline or reference phase similar to that which the forward fringe is presumed to provide. The presence of this reference phase after the offset of the signal apparently makes the phase shift associated with the signal-plus-noise waveform more discernible, thus leading to higher detectability. However, for reasons not yet clear, the presence of a baseline or reference phase after the offset of the signal (backward fringe conditions) does not make the signal-plus-noise phase shift as discernible as do either the presence of that same reference phase before the onset of the signal (forward fringe condition) or the presence of that same reference phase both before signal onset and after signal offset (continuous masker condition).  相似文献   

14.
Masked vibrotactile thresholds at the index fingertip were measured as a function of masker intensities, which were applied to the thenar eminence of the same hand. Test and masker frequencies were selected so that the Pacinian and non-Pacinian receptor systems were selectively activated. Remote-site masking was effective only when both masker and test stimulus were within the frequency range of the Pacinian system. Cross-channel masking did not occur.  相似文献   

15.
Seven parakeets were trained to avoid shock during pure-tone stimulation. A modified method of limits was used to measure detection thresholds of the pure tones. The intensity of masker tones, at numerous frequencies, was varied in order to measure the masked threshold of a probe-tone signal set at a fixed frequency and intensity. Masking curves were obtained for three probe tones (.63, 1.6, and 2.5 kHz) at each of five sensation levels (10, 20, 30, 40, and 50 dB). The masking curves from this procedure are frequently referred to as "psychophysical tuning curves" and provide an indication of frequency selectivity. The results are compared with analogous data in other species and suggest that frequency analysis in the parakeet ear is somewhat less accurate than in the mammalian ear.  相似文献   

16.
The binaural auditory system exhibits certain advantages over the monaural system when detecting a tonal signal in a background of masking noise. These advantages have been described in detail and are referred to as masking-level differences, or MLDs. It has been demonstrated, for example, that performance in detecting a tonal signal that has been reversed in phase at one ear relative to the other ear is about 15–17 dB better than detection of the same signal in-phase at the two ears when masked by moderately intense masking noise that is in-phase at the two ears. The explanations for this phenomenon fall into two general categories, and both types of explanations are based upon the interaction of the tonal signal and masker when they are added together. In the present paper, data are presented which indicate that an MLD of at least 4–5 dB can be obtained in a binaural masking experiment in which the offset of the tonal signal precedes the onset of the noise masker.  相似文献   

17.
Vibrotactile patterns, generated on the 6×24 array of the Optacon, were presented to subjects’ left index fingertips. The subjects identified these patterns in the absence of any masking stimuli and in the presence of spatially adjacent masking stimuli. The amount of interference in recognizing the patterns was measured as a function of the interval between target and masker onsets. Masking functions similar to those reported in visual metacontrast studies were found; that is, more masking occurred when masker onset followed target onset by 25 to 50 msec than when onsets were simultaneous. Subjects showed more metacontrast when masker energy was reduced, a finding paralleled in the visual literature. The relevance of some models of visual metacontrast to the tactile findings is discussed.  相似文献   

18.
Under a noisy “cocktail-party” listening condition with multiple people talking, listeners can use various perceptual/cognitive unmasking cues to improve recognition of the target speech against informational speech-on-speech masking. One potential unmasking cue is the emotion expressed in a speech voice, by means of certain acoustical features. However, it was unclear whether emotionally conditioning a target-speech voice that has none of the typical acoustical features of emotions (i.e., an emotionally neutral voice) can be used by listeners for enhancing target-speech recognition under speech-on-speech masking conditions. In this study we examined the recognition of target speech against a two-talker speech masker both before and after the emotionally neutral target voice was paired with a loud female screaming sound that has a marked negative emotional valence. The results showed that recognition of the target speech (especially the first keyword in a target sentence) was significantly improved by emotionally conditioning the target speaker’s voice. Moreover, the emotional unmasking effect was independent of the unmasking effect of the perceived spatial separation between the target speech and the masker. Also, (skin conductance) electrodermal responses became stronger after emotional learning when the target speech and masker were perceptually co-located, suggesting an increase of listening efforts when the target speech was informationally masked. These results indicate that emotionally conditioning the target speaker’s voice does not change the acoustical parameters of the target-speech stimuli, but the emotionally conditioned vocal features can be used as cues for unmasking target speech.  相似文献   

19.
Cutaneous receptors sensitive to high-frequency vibration produce spatial summation at threshold levels of stimulation, whereas the response of the receptor population sensitive to low frequencies appears to be independent of contactor size at threshold. Reports have been made of a phenomenon in which the presumably nonsummating population of mechanoreceptors produce spatial summation at suprathreshold levels. A possible explanation concerns the relative signal-to-noise ratios of cutaneous mechanoreceptor systems. By selectively masking the systems with narrow-band and wide-band noise, it can be shown that any combination of signal frequency, masking noise, and contactor size that predominantly activates either system results in a linear effect of the masker on the threshold of the signal. Combinations of the experimental variables that activate both receptor systems simultaneously reduce the effect of the masking by one-half. This is interpreted as evidence of an interactive process between receptor systems within the central nervous system. The effects of signal-to-noise ratio and intrasensory interactions are discussed.  相似文献   

20.
Threshold elevations (TE) were determined for three Os at a test site on the left thigh with a masker placed singly at each of 10 widespread loei on the trunk. Although lateral changes in masker placement did not produce a significant alteration in TE (p> .10), there was a systematic decrease in TE with longitudinal separation between masker and test sites on the body. Appropriate manipulations of the time interval between masker and test signals were found effective in offsetting these decreases. It appeared that longitudinal separations were differentially affecting temporal delays by producing unequal neural distances from the test and masker sites to the CNS. There were, however, some spatial changes that could not be accounted for by temporal offsets. Thresholds at a finger test site were significantly less elevated (p< .01) by contralateral placement of maskers than by ipsilateral placement, and the particular test site chosen for threshold determinations, either index finger or thigh, determined the amount of TE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号